Get a Quote
Experiment 4: Purification of Liquids by Distillation

Experiment 4: Purification of Liquids by Distillation

4. Your heating mantle has a separate cord – be sure to securely plug and twist the cord on, then slide the heating mantle under the round bottom flask and adjust the iron ring so the flask is snuggly nestled inside the mantle. Plug the heating mantle into the Variac (which should be set to “off” and a voltage of 0). DO NOT PLUG THE

More details
Classification of Carvone and Semicarbazone

Classification of Carvone and Semicarbazone

a greased vacuum-sealed system that begins with boiling a liquid using a heating mantle (Greased to make sure air does not escape and is disassemble). Afterwards, the vapor at a low pressure will ... Whatever plus or minus is defined for the ... for the Variac dial, increased by five about every 5 minutes. When temperature reached 30.3 ˚C,

More details
11739 Glas-col heating Mantle no cord 180 watt 0402

11739 Glas-col heating Mantle no cord 180 watt 0402

BOX/SKID/CRATE WEIGHT:3. Email to friends Share on Facebook - opens in a new window or tab Share on Twitter - opens in a new window or tab Share on Facebook - opens in a new window or tab Share on Twitter - opens in a new window or tab

More details
Heating mantle with issues - Equipment - Science Forums

Heating mantle with issues - Equipment - Science Forums

Feb 12, 2017 THIS is why you should be extremely careful when buying equipment on eBay, I finally thought maybe this is a 110-220 issue, so I popped off the variac housing and voila, sure enough the controller is rated 220-250v and it simply has a standard US plug attached.

More details
Heat Sources and Heating Baths - Stony Brook University

Heat Sources and Heating Baths - Stony Brook University

Heating Bath SOP 2013 1 Standard Operating Procedure Heat Sources and Heating Baths 1. Procedure/Hazardous Material: Includes, but not limited to ovens, hot plates, heating mantles and tapes, oil baths, salt baths, sand baths, hot-air guns, and microwave ovens. 2. Department: Campus wide 3. Revision Date: February 2013 4. Special Notifications:

More details
Heating Mantle - Zhengzhou Zylab Instruments Co. Ltd

Heating Mantle - Zhengzhou Zylab Instruments Co. Ltd

Heating Mantle. Application: Be suitable for high temperature heating of flask in laboratory. Introduction: Light-weight insulated materials can be shaped into hemispherical heat Insulator by high voltage, with high temperature resistant plastic casing, or casing with structural steel cold rolling plate baked enamel or electrostatic spray.

More details
Hydration of 1-Hexene Flashcards Quizlet

Hydration of 1-Hexene Flashcards Quizlet

Heating mantle. In order to heat a round bottom flask in a heating mantle, plug the heating mantle into a Variac or Powermite. Turn the heat up gradually, and do not exceed 50-60% of the maximum output of the device. ... Quizlet Plus for teachers. Help. Sign up. Help Center. Honor Code. Community Guidelines. Teachers. About. Company. Blog ...

More details
Heating - Glas-Col

Heating - Glas-Col

Heating. Laboratory heating systems are subject to numerous safety standards and protocols because they are so readily available and potentially hazardous. Great concerns are taken to ensure that heating systems are manufactured to exacting standards and from the most thermally-efficient materials. Yet there are still individual considerations ...

More details
The Glassware Gallery: Heating Sources

The Glassware Gallery: Heating Sources

Mar 15, 2017 One of the most popular and safest methods to heat a reaction mixture in a synthetic organic, inorganic, or organometallic laboratory is a heating mantle, a resistively heated flexible fiberglass shell that conforms to the shape of the reaction flask.Most heating mantles are hemispherical in design and come in a variety of sizes designed to fit round bottom flasks from …

More details
Rheostat to electric heating element? - Houzz

Rheostat to electric heating element? - Houzz

No one uses rheostats for controlling things anymore. the device is a dimmer, and it uses a triac to chop up the voltage waveform. It will be fine for a heating element, but you need one with a power rating (watts) at least as large as the heating …

More details
Simple Distillation Lab Flashcards - Quizlet

Simple Distillation Lab Flashcards - Quizlet

Simple Distillation. -Very old chemical/physical technique. -Boiling only ONE substance. -Substance in still pot, receiving heat from a heating mantle. -Still pot in this experiment = Round bottom flask. *Purpose = Determine the boiling point of the unknown liquid compound in the still pot. In Lab Objectives.

More details
Heating Mantle Adapter -

Heating Mantle Adapter -

Standard Test Methods for Reducible Sulfur in Paper. gas inlet tube adapter with perforated bulb, a 60-mL pear-shaped funnel, a 200-mm West condenser, a side-arm adapter, and a heating mantle with variable power supply. 8.2 Absorption Apparatus (Fig. 1), consisting of a 100-mL amber or low-actinic flask in a suitable ice bath. 8.3 Colorimeter or Spectrophotometer to …

More details
Experiment 10: The Synthesis of Artificial Hyacinth

Experiment 10: The Synthesis of Artificial Hyacinth

The flask is heated with a heating mantle until the reactants boil. ... 119 on the Variac. 5. Allow the mixture to reflux for 30 minutes after starting to boil. The timing of ... bisulfate and sodium bromide, plus water and sulfur dioxide: Br2 + 3NaHSO3 2NaBr + NaHSO4 + H2O + SO2 10. To the rapidly stirred (stirrer set at 6-7) reaction ...

More details
Exp 3 - Distillation - F17

Exp 3 - Distillation - F17

The flask is situated into an appropriately sized heating mantle. The heating mantle should not be plugged directly into an outlet. The heating mantle should be plugged into a variable voltage controller (variac), which is then plugged into a wall outlet. Make sure the variac is turned down to zero initially. Do not plug the variac into an ...

More details
I I III I 111 I 11 I - Oak Ridge National Laboratory

I I III I 111 I 11 I - Oak Ridge National Laboratory

The flask was heated with a heating mantle, and the rate of heating was controlled by a Variac. In the solution studies reported in the later sections of this report the flask was heated in an oil bath to give a more even distribution of heat within the solution.

More details
Organic laboratory Heat Sources

Organic laboratory Heat Sources

The heating element within the insulated mantle is wired to plug i nto a Variac controller which in turn is plugged into a 115 volt outlet. Never plug the mantle directly into a 115 volt outlet; you might burn out the heating element. In operat ing a heating mantle, the controller should initially be off and reading zero voltage.

More details
Chem 211 - Techniques - Wellesley College

Chem 211 - Techniques - Wellesley College

The heating mantle would be raised to heat the apparatus, as shown in the picture on the left. Because the entire apparatus is raised above the level of the table, the heating mantle can be lowered, as shown on the right, to cool the flask quickly. ... It is very important to include boiling stones in the flask and to plug the heating mantle ...

More details
Heating Mantles - Electrothermal Heating Mantle

Heating Mantles - Electrothermal Heating Mantle

This economical heating mantle by Electrothermal handles 500mL flasks and is ideal for use in teaching and industrial laboratories. Supplied with a support rod clamp. Non-slip feet and a 6.5-foot (2m) line cord. Flexible designed heating element (non-replaceable) ensures efficient heat transfer and fast boiling times.

More details
Isolation of Limonene from Orange Peels Name:huaren

Isolation of Limonene from Orange Peels Name:huaren

Using a volumetric flask to prepare a solution. Polarimetry (sections 17.2-17.5), including reading a Vernier scale. A document regarding the Vernier scale has been posted on Canvas Equipment Mini (14/20) glassware kit, including separatory funnel 500-mL heating mantle and variac 25-mL volumetric flask with stopper. Safety . Limonene. Irritant.

More details
MASSACHUSETTS INSTITUTE OF TECHNOLOGY

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

will crack the dimer as follows: first connect the heating mantle to a Variac, and turn on the water flow to the condenser. Check that all joints are well sealed and that the apparatus is stable and tight. Insert a syringe needle into the septum of the receiving flask, flush the system for 1 min with nitrogen. After 1 min remove the vent syringe

More details
Related Post

Send Message to Us

48-hour idling test machine before leaving the factory. You can take the materials to the factory test machine. We will customize the solution according to your needs.

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.

<script type="text/javascript" src="https://v1.cnzz.com/z_stat.php?id=1281089964&web_id=1281089964"></script>