Get a Quote
Rotary evaporator De Qumica

Rotary evaporator De Qumica

A common basic operation in the organic chemistry laboratory is the removal of a volatile organic solvent from a reaction mixture or a process such as liquid-liquid extraction. Although this operation could, in principle, be performed by simple distillation , the fastest and most convenient method is the use of a rotary evaporator (rotovap) for ...

More details
Benchtop Rotary Evaporators -

Benchtop Rotary Evaporators -

Benchtop rotary evaporators for the efficient and gentle removal of solvents from samples in RD and QC-scale applications. These rotary evaporators accommodate evaporation flasks of 5 liters or less. Options include motorized lifting arms, digital vs. manual controls, integrated vacuum control, and the types of condensers which they can accommodate.

More details
Percentage of collection of solvent composition recovered from rotovap?

Percentage of collection of solvent composition recovered from rotovap?

DCM can also extract BTEX but not as well as CS 2 because DCM is a less polar solvent (ε = 8.93, =1.55). The extraction capacity of acetone is …

More details
Ai SolventVap 50L Rotovap with Huber CS100 Chiller

Ai SolventVap 50L Rotovap with Huber CS100 Chiller

Example:The following table is a list of a variety of substances ordered by increasing vapor pressure (in absolute units). Ai SolventVap 13-gallon/50L (evaporating flask capacity) series rotary evaporators come with vertical glassware and digital temperature/rotation control. Its optimized bath volume allows for rapid heat-up times.

More details
Ai SolventVap 50L Rotovap with Huber CS100 Chiller

Ai SolventVap 50L Rotovap with Huber CS100 Chiller

Features. Dual receiving flask comes standard, a $1,700 value. Now includes a stainless steel 50L evaporating flask carrier with silicone cushions (a $399 value), custom made for Ai 50L SolventVap series rotary evaporators. This carrier can be placed on top of our 50L SolventVap's water bath for easy loading and unloading.

More details
Ecodyst Hydrogen Rotary Evaporator - Ecodyst

Ecodyst Hydrogen Rotary Evaporator - Ecodyst

Mar 06, 2021 The main applications are solvent recycling, extractions, sample concentration and isolation of solvent mixtures. Rotovaps consist of a heating fluid bath, rotating motor, evaporating flask, condenser, collection flask, and the vacuum source. Conventional rotovap condensers require external sources of cooling materials such as dry ice, liquid ...

More details
Erowid Chemistry Vaults : Organic Solvents Table of Properties

Erowid Chemistry Vaults : Organic Solvents Table of Properties

Notes: M in the water solubility column means completely Miscible in water. The values in the table below except for relative polarities have been extracted from MSDS compilations (see section II-B-4 of the Chemistry Webercises Directory) or the ChemFinder Web Server.Values for relative polarity have been extracted from: Christian Reichardt, Solvents and Solvent Effects …

More details
Question Using hexane as solvent for solvent extraction still or rotovap?

Question Using hexane as solvent for solvent extraction still or rotovap?

Oct 04, 2017 Sep 27, 2017. 34 y/o from Azores, Portugal. Docta said: ↑. Start with Hexane it is a far superior solvent for extracting of things such as cannabis oils, when I say Hexane I mean n- hexane the aliphatic hydrocarbon. The alcohol is then used as a scrubber after the hexane has been evaporated to remove any residue.

More details
Ethanol Removal in Cannabis Applications Blog

Ethanol Removal in Cannabis Applications Blog

Oct 31, 2019 They are also environmentally-friendly and allow for the recovery and reuse of the solvent. With the right equipment and controls, rotovap processes have excellent repeatability. Optimal Rotovap Operating Conditions for Ethanol Removal. The recommended vapor temperature for ethanol extraction is 25–30C.

More details
Rotovap - Dartmouth College

Rotovap - Dartmouth College

Rotary Evaporator (Rotovap) Even though the rotary evaporator (or rotovap for short) looks pretty complicated, it's really pretty simple. The purpose of the rotovap is to remove low boiling organic chemicals, usually solvents, from a mixture of compounds. The rotary evaporator is the method of choice for solvent removal in the modern organic ...

More details
Rotary Evaporator - Part 3 -

Rotary Evaporator - Part 3 -

Rotary evaporators are currently for sale with the favorable price and sincere service. A rotary evaporator (rotovap or rotatvap) refers to a kind of equipment for solvent evaporation under reduced pressure, which is composed of a vacuum system, a heated water or oil bath, a condenser and a motor that rotates the evaporation flask. As its name suggests, what is …

More details
Rotary Evaporator Fact Sheet - UMass Amherst

Rotary Evaporator Fact Sheet - UMass Amherst

solvent) and clog traps. Water aspirators should not be used as these can allow solvent vapors to enter drains and waste large volumes of water. 5. Check all glassware for visible chips, cracks or scratches before using. Handle glassware with care at all times. 6. Always use a cold trap in between the rotovap and the pump. Never use a liquid

More details
10L-30L Rotary Evaporator Ethanol extraction CBD technology ... - Rotovap

10L-30L Rotary Evaporator Ethanol extraction CBD technology ... - Rotovap

The 10L-30L rotary evaporators, whether electric or manual lift one, are currently for sale. A rotary evaporator, known as “rotavap” or “rotovap” as well, refers to a kind of equipment for solvent evaporation under reduced pressure, which is composed of a vacuum system, a heated water or oil bath, a condenser and a motor that rotates the evaporation flask.

More details
Rotavapor R-300

Rotavapor R-300

The Rotavapor R-300 meets the highest expectations of convenience and versatility in rotary evaporation. Its modular design allows the R-300 to be extended to a fully integrated system where a central interface regulates each component. Evaporating flask size: 50 – 5000 mL. Lift mechanism: Manual or automatic. Temperature range: 20 – 220 C.

More details
Rotary Evaporator Trap at Thomas Scientific

Rotary Evaporator Trap at Thomas Scientific

Vapor tube/bump trap adapter is designed to be used with the Bchi R-200/205 rotary evaporators. This adapter combines a vapor tube adapter and a bump trap. Trap has an extra coarse fritted disc sealed between the lower inner joint and the top flange. Adapters have a 50mm OD top flange….

More details
Related Post

Send Message to Us

48-hour idling test machine before leaving the factory. You can take the materials to the factory test machine. We will customize the solution according to your needs.

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.

<script type="text/javascript" src="https://v1.cnzz.com/z_stat.php?id=1281089964&web_id=1281089964"></script>