Get a Quote
How to use a Rotary Evaporator

How to use a Rotary Evaporator

Apr 01, 2010 The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated). It is highly advisable to start with a clean bump bulb in case something bumps over after all! This would allow the experimenter to recover the solution or solid. 3.

More details
Rotary Evaporators Fisher Scientific

Rotary Evaporators Fisher Scientific

Bump Trap, 500mL, Rotary Evaporator, Modified, 24/40 Top Outer, 24/40 Lower Inner. Similar to CG-1320, but with the addition of two 4mm drain holes at the base of the inner tube to allow solvent to drain back into the evaporation flask. Traps have a 24/40 top outer joint and the listed size of lower inner joint. Encompass Procurement Services.

More details
Rotary Evaporator Instruction Summit Research

Rotary Evaporator Instruction Summit Research

Dec 14, 2016 We’ve pioneered a rotary evaporator operating process that has made made progressive waves within the industry. What was once a long arduous process of filling the flask falsely spread information is now publicly corrected, here at Summit Research. ... Connect output of condenser coil to the chiller return port. Connect vacuum port from ...

More details
How to Clean Your Rotary Evaporator Blog

How to Clean Your Rotary Evaporator Blog

Dec 16, 2019 Connect one socket to the rotovap (where the evaporation flask would usually go). You can secure it in place or hold it with one hand. Note, the flask should not be set to spin during this process. Use your thumb to close the second socket of the two-neck flask. Set the vacuum pump to around 250 mbar and switch it on.

More details
What is Rotary Evaporator Working Principle? - Rotovap

What is Rotary Evaporator Working Principle? - Rotovap

Feb 27, 2019 A rotary evaporator (rotovap or rotavap) evaporates solvents from samples by utilizing the principle that the solvent will have a lower boiling point at a reduced pressure. Specifically speaking, the stepless speed regulation is adopted to make the evaporation flask rotate at a constant speed. By the rotation, materials can form a large area of ...

More details
How Does a Rotary Evaporator Work - USA Lab

How Does a Rotary Evaporator Work - USA Lab

Mar 01, 2021 To begin the process of rotary evaporation, a solvent is placed in a round-bottomed flask in the water bath of the rotary evaporator system. The system’s pressure is then reduced below atmospheric pressure through the use of a vacuum pump. Reducing the pressure in the rotary evaporator has numerous benefits. Namely, the reduced pressure ...

More details
Rotary Evaporator Fact Sheet - UMass Amherst

Rotary Evaporator Fact Sheet - UMass Amherst

Rotary Evaporator Fact Sheet . What are Rotary Evaporators? A rotary evaporator (also called as “rotavap” or “rotovap”) is a device used in labs for the efficient and gentle removal of solvents from samples by evaporation. The picture on the right shows what a typical rotary evaporator includes. What are Potential Hazards?

More details
Rotary Evaporator Cost For Leasing Financing in 2022

Rotary Evaporator Cost For Leasing Financing in 2022

Rotary evaporators range in size and volume capacity, with options available to meet space and usage specifications, as well as digital displays for ease of use. ... The lessee has the option to return the equipment to the lessor, renew at a discounted rate, or purchase the instrument for the fair market value. Monthly payments are also 100% ...

More details
Standard Operating Procedure - Rotary Evaporator

Standard Operating Procedure - Rotary Evaporator

the rotary evaporator control panel. 15. Use the dial on the rotary evaporator control panel to set the desired spin speed of the condenser. 16. If the desired evaporation should be timed, press the timer button on the rotary evaporator control panel and use the dial to set a time in minutes, or press the int

More details
Rotary Vacuum Evaporator at Thomas Scientific

Rotary Vacuum Evaporator at Thomas Scientific

The rotary evaporator R-100 is a high-quality, entry level Rotavapor to meet the essential needs in classical laboratory applications. It is capable of a manually adjustable rotation speed of 20 to 280 rpm and equipped with an action jack lift for manual …

More details
ROTARY EVAPORATORS - 2L - Page 1 - USA Lab

ROTARY EVAPORATORS - 2L - Page 1 - USA Lab

USA Lab Dry Ice Dewar Condenser Cold Trap for 2L and 5L Rotary EvaporatorsOur Dry Ice Dewar Condenser is an alternate method of condensing for people who looking to usMSRP:Was:Now:$295.00 - $345.00. Options. USA Lab. 2L RE-200A Rotary Evaporator Replacement Vapor Duct with Integrated PTFE Seal. Our Replacement Vapor Duct fits into …

More details
ROTARY EVAPORATORS - 5L - Page 1 - USA Lab

ROTARY EVAPORATORS - 5L - Page 1 - USA Lab

USA Lab Dry Ice Dewar Condenser Cold Trap for 2L and 5L Rotary EvaporatorsOur Dry Ice Dewar Condenser is an alternate method of condensing for people who looking to usMSRP:Was:Now:$295.00 - $345.00. Our 5L Bump Trap fits our 5L RE-1005 Rotary Evaporator Systems. The condenser is constructed with th.

More details
50 Liter Rotary Evaporator in Los Angeles CA USA

50 Liter Rotary Evaporator in Los Angeles CA USA

Used Automatic Lifting 50 Liter Rotary Evaporator in Los Angeles, CA. Manufacturer: Automatic Lifting 50 Liter Rotary Evaporator; The unit was removed from an operating environment and is in good physical condition. The unit is missing some components however you will receive everything in the photos northing more or less. For more details ...

More details
Rotary Evaporator Trap at Thomas Scientific

Rotary Evaporator Trap at Thomas Scientific

Vapor tube/bump trap adapter is designed to be used with the Bchi R-200/205 rotary evaporators. This adapter combines a vapor tube adapter and a bump trap. Trap has an extra coarse fritted disc sealed between the lower inner joint and the top flange. Adapters have a 50mm OD top flange….

More details
Rotary Evaporators - Stuart Equipment

Rotary Evaporators - Stuart Equipment

• The RE401 rotary evaporator comes with a vertically orientated glass condenser for distillation of solvents with higher boiling points. 20% narrower than RE400 saving space. • The RE402 rotary evaporator comes with a vertically orientated, cold …

More details
Related Post

Send Message to Us

48-hour idling test machine before leaving the factory. You can take the materials to the factory test machine. We will customize the solution according to your needs.

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.

<script type="text/javascript" src="https://v1.cnzz.com/z_stat.php?id=1281089964&web_id=1281089964"></script>