SOP for Operation and Cleaning of Hot Air Oven

SOP for Operation and Cleaning of Hot Air Oven

5.2.1 Wipe the surface, walls, top, bottom and trays of the oven with dry lint free cloth on the daily basis so that there will be no dust particles in the oven. 5.2.2 Wipe all the parts and the outer surface of the Oven with wet lint free cloth soaked in purified water, on weekly basis and fill the weekly cleaning record. 6.0 ABBREVIATION

More details
Total DM by oven drying - UW Soil and Forage LAB

Total DM by oven drying - UW Soil and Forage LAB

8.6 Insert samples into preheated oven at 105 C and dry for 3 hours after oven has returned to temperature. 8.7 Move samples to desiccator, seal desiccator and allow to cool to room temperature. Do not allow sample to remain in desiccator for more than 2-3 hours. 8.8 Weigh dish and dried sample, recording weight to nearest 0.001 g.

More details
Atterberg Limits -

Atterberg Limits -

A mass of wet soil, M 1, is placed in a porcelain dish 44.5 mm in diameter and 12.5 mm high and then oven-dried. The volume of oven-dried soil is determined by using mercury to occupy the vacant spaces caused by shrinkage. The mass of mercury is determined and the volume decrease caused by shrinkage can be calculated from the known the density ...

More details
Air dry vs oven dry soil sample for hydrometer test - Eng-Tips Forums

Air dry vs oven dry soil sample for hydrometer test - Eng-Tips Forums

Apr 05, 2009 The soil will be oven dry at begining. after having the total weight, the sample will be grinded with a pestle. Sieve it over 2mm sieve. The portion retained will be washed and sived again. The percentage of the soil passing can be calculated then. The sub-sample will be taken from the portion passing the 2mm sieve for the hydrometer analysis.

More details
Soil Drying Agents: How to Dry Out Soil - Mintek Resources

Soil Drying Agents: How to Dry Out Soil - Mintek Resources

Aug 06, 2020 Lime-based drying reagents, such as Calciment LKD, also known as Lime Kiln Dust, and Quicklime, will help quickly dewater wet soils to reach optimum moisture content (OMC). The reagent is applied at a pre-determined dose rate (typically 2%- 5% depending on soil conditions), mixed into the soil and hydrated. Hydration is required to create the ...

More details
Kenmore gas oven works intermittently -

Kenmore gas oven works intermittently -

Jan 14, 2001 Gas Kitchen Appliances, Dryers and BBQ's - Kenmore gas oven works intermittently - When I turn my gas oven on, about 50% of the time the glowbar comes on and the oven lights. The other times I turn on the oven and the glowbar fails to glow and the oven fails to operate. ... Should you not want to go thru this proceedure, contact the local ...

More details
Determine pH of Soil Samples - How To Test Measure

Determine pH of Soil Samples - How To Test Measure

Jul 21, 2021 Alternative Testing—Method B. 1. Place soil sample about full in sample jar and add distilled water to cover soil. 2. Cap the jar and shake the soil vigorously a few times. 3. Let mixture stand 10 minutes to dissolve the salts in the soil. 4. Calibrate the pH tester with a pH 7 and a pH 10 buffer solution.

More details
How does air dry soil differ from oven dry soil?

How does air dry soil differ from oven dry soil?

Jun 24, 2020 If the sponge is placed in an oven at 105 C, it will lose water, and therefore lose mass. Similarly, air-dried soils contain water. Air-dried sands retain the least water, while air-dried clays retain the most relative to oven drying. Correspondingly, what is air dried soil? In soil science and biogeochemistry, the term “air-drying ...

More details
SOIL SURVEY LABORATORY METHODS MANUAL - USDA

SOIL SURVEY LABORATORY METHODS MANUAL - USDA

Laboratory Preparation of Soil Samples 1B 9, 587 Standard Air-Dry 1B1 11 Square-hole 2-mm Sieve 1B1a 12 Round-hole 2-mm Sieve 1B1b 12 Field Moist 1B2 15 ... Air-dry or Oven-dry to 1/3-Bar Tension 4D1 177. CONTENTS METHOD TITLE METHOD PAGE CODE iii Micromorphology 4E 179, 596 Thin Sections 4E1 179, 596

More details
Cleaning and Sanitation Procedures Module Bakery

Cleaning and Sanitation Procedures Module Bakery

Oven A. Commercial Ovens 1) Wearing chemical resistant gloves and chemical splash goggles. 2) Apply product (undiluted) to the bottom of the oven, then sides and top evenly. 3) Allow products to stand 10 minutes in warm oven, or 25 minutes in cold oven before gently agitating soil with a synthetic pad or brush. 4) Wipe surface, removing major soil.

More details
OVEN DRYING SAMPLES - USGS

OVEN DRYING SAMPLES - USGS

Place samples in oven at 60 degrees F for at least 24 hours or until cracks appear in sediment. Check oven door to make sure it latches. Place samples in desiccator when removed from oven to cool and to avoid getting moisture from the air in your samples. Weigh samples on a balance to get the dry weight.

More details
Soil Sample Collection and Analysis Procedures

Soil Sample Collection and Analysis Procedures

soil to use in the coring device is established by weighing a similar soil sample before coring the analytical ... A dry weight vial without methanol preservation is also required for every sample. Clean the vial threads to assure a good seal with the cap provided. b) Diesel range organics (DRO) sampling: Collect DRO samples according to the ...

More details
Laboratory Procedures for Analysis of Exploration

Laboratory Procedures for Analysis of Exploration

Soils / Sediment / Sludges / Reusable Material. pH SW-846 9045C, EPA 150.2^ TPH (Total Petroleum Hydrocarbons) SW-846 1664 HEM/SGT / SW-846 9071 ... 5.5 Place the pan and its contents in an oven at 38 C* until a constant weight is achieved. Moisture content will be determined on this sample, however, additional material may need to be dried so ...

More details
A GUIDE TO TESTING SOIL FOR HEAVY METALS

A GUIDE TO TESTING SOIL FOR HEAVY METALS

State University5 both recommend testing soil every 2-3 years to maintain optimal soil fertility. The University of Georgia Exten-sion recommends testing soil fertility every 1-2 years.6 To minimize the time spent collecting samples and costs, we recommend re-testing your soils for heavy metals as often as

More details
Determination of Moisture Content in Soil - JoVE

Determination of Moisture Content in Soil - JoVE

Subtract the weight of the empty dish from the full dish to acquire the moist soil weight. Next, dry the soil overnight in an oven set to 105 C. On the next day, carefully remove the soil samples from the oven using tongs. Place the soil samples on the bench top to cool. When the dry soil samples are cool, reweigh them and record the total ...

More details
TROXLER MODELS 3400 4640 -

TROXLER MODELS 3400 4640 -

Take four or more gauge/oven-dry sample pairs as follows; perform and record a 1 min. gauge measurement, then collect a soil sample from the same spot, keeping in mind the gauge’s depth of measurement. Repeat four or more times in locations with similar moisture content. Seal the soil sample as to not lose any moisture. Find

More details
11-R-16: Understanding Oven-Dry Weight - Forest Resources

11-R-16: Understanding Oven-Dry Weight - Forest Resources

The % oven-dry solids or %OD is calculated by: % Moisture content dry basis = (wet weight – dry weight)/dry weight *100. This expression is the most commonly used expression of moisture content in wood. It is easily converted to %OD by subtracting the %MC dry basis from 100. % Moisture content wet basis = (wet weight – dry weight)/wet ...

More details
Particle and Bulk Density - Agrosphere International

Particle and Bulk Density - Agrosphere International

Where bulk density is computed on a moisture-free (i.e. oven-dry) basis, the amount of water in the soil is ignored1. Note that bulk density is obtained by dividing by the total “bulk” sample volume, including all particle solids and pore space, by the oven-dry soil mass. In contrast, density is obtained by

More details
Standard Operation Procedures (SOP) for IITA Seedbank

Standard Operation Procedures (SOP) for IITA Seedbank

• Weigh remaining the dry matter using a precision balance. (During the rainy season, maintain the sample in desiccators during the weighing process to avoid sample rehydration.) Minimum data capture: Fresh weight before oven drying, dry weight after oven drying, derived water content. Use a precision balance. 10. Germination