Get a Quote
Marijuana Terpene Extraction with Apeks Supercritical.

Marijuana Terpene Extraction with Apeks Supercritical.

Apeks offers all its customers a free two-hour, hands-on class demonstrating how to winterize oil. Classes are held at the Apeks Supercritical manufacturing facility in Johnstown, Ohio. Non-customers can attend as well for a fee.Steps to winterization: Mix the extract with 200-proof alcohol and put in a deep freezer for a minimum of 24-48 hours.

More details
Operation Manual Rotavapor R II

Operation Manual Rotavapor R II

Appropriate warnings in this manual serve to make the user alert to these residual dangers. 2 .5 .1 Instrument-related hazards Pay attention to the following safety notices: WARNING Potentially hot surfaces during operation, especially at the water or oil bath (up to 95 C). • Always be aware of the risk of being burned.

More details
Rotavapor 210 215 en

Rotavapor 210 215 en

Appropriate warnings in this manual serve to make the user alert to these residual dangers. 2.5.1 Instrument-related hazards Pay attention to the following safety notices: WARNING Potentially hot surfaces during operation, especially at the water or oil bath (up to 180 C). Always be aware of the risk of being burned.

More details
Zymark TurboVap LV Evaporator 43750/20 Turbo Vap

Zymark TurboVap LV Evaporator 43750/20 Turbo Vap

Buchi Rotavapor R-124 Rotary Evaporator quantity ... Although we make every attempt at accuracy, some accessories may appear different upon arrival; accessories photographed above are for demonstration and may be generic in comparison to actual accessories included. Connections, cables, ports, and voltage capabilities may differ pending your ...

More details
Standard Operating Procedure - Rotary Evaporator

Standard Operating Procedure - Rotary Evaporator

condenser. Make sure the flask is clean before use. 5. Open the cabinet doors directly below the rotary evaporator. Since the chiller is turned sideways, the back of the chiller is on the right side of the cabinet and the front of the chiller is located on the left side of the cabinet. 6.

More details
Rotavapor at Thomas Scientific

Rotavapor at Thomas Scientific

Cover Heating Bath B-491. Buchi. Two heating baths are available for the Rotavapor R-210 and R-215. With a heating capacity of 1300 W, they provide enough energy for a fast distillation. The mayor differences between the bath B-491 and B-495 are the bath size and temperature range. The B-491 can be used as a water and oil bath up….

More details
UW SWAP Online Auction - Rotavapor RE

UW SWAP Online Auction - Rotavapor RE

Does not include stand Includes power cord Model # Rotavapor RE Serial # 216086 Overall dimensions : 6.75H x 10W x 10.25D Cosmetic condition : good Functionality : partially tested; powers on, observed rotation ... Make Offer. Remaining Time 7 Days, 6 Hours High Bidder: 0 Bid(s) UW SWAP Online Auction will bid incrementally for you up to your ...

More details
Rotavapor: why is it fundamental in a laboratory? - Kalstein

Rotavapor: why is it fundamental in a laboratory? - Kalstein

Feb 09, 2022 The rotavapor is designed to evaporate organic or aqueous solvents; these equipment have a sample rotation system, revolution control and a thermoregulated bath to keep the sample at a controlled temperature; these characteristics of the apparatus make it indispensable in laboratories to be able to handle certain samples and to be able to ...

More details
Instructions for Using Buchi Rotavapor - Haverford

Instructions for Using Buchi Rotavapor - Haverford

Instructions for Using Buchi Rotavapor 1. Turn on the water supply to the aspirator pump (the tap is labeled) so a slow, but steady, stream of water comes out of the overflow port on the side of the blue tank that is part of the vacuum aspirator pump unit, then turn on the power switch to start the vacuum aspirator pump motor. 2.

More details
How do I evaporate water and ethanol using a rotary

How do I evaporate water and ethanol using a rotary

Jan 20, 2022 However the US commonly uses ~10% ethanol gasoline. What I may suggest to make the rotavap operate more quickly is to increase the ethanol %, decrease pressure and sparingly increase temperature ...

More details
Rotavapor manuals

Rotavapor manuals

Jan 31, 2020 buchi rotavapor r-210 manual. buchi v-100buchi rotavapor. BUCHI reserves the right to make changes to the manual as deemed necessary This manual describes the Rotavapor R-220 SE and provides all information. Operation Manual (Original) Rotavapor R-300. 11593738 en. Publication date: 08.2015, Version B. BUCHI Labortechnik AG. …

More details
Home Environmental Health Safety UCI

Home Environmental Health Safety UCI

Make sure to empty the solvent reservoir into the appropriate waste container and clean the bump trap after each use. Remove the water from the hot water bath when finished using the rotovap, this will prevent it from evaporating and leaving behind a residue. Residues are difficult to remove and decrease the efficiency of the water bath.

More details
Rotavapor R-210/215

Rotavapor R-210/215

Oct 22, 2021 The R-210/215 Advanced combines the Rotavapor with the Vacuum Controller V-850 and is suitable for all standard Rotavapor tasks. The R-210/215 Professional includes the Vacuum Controller V-855 and the stage probe for auto distillation (for condenser types V and S). The appeal of this arrangement is its versatility.

More details
Rotavapor R-250 Pro Operation Manual

Rotavapor R-250 Pro Operation Manual

Operation Manual (Original) Rotavapor R-250 Pro 11594225 Publication date: 03.2022 Version B BCHI Labortechnik AG Meierseggstrasse 40 Postfach CH-9230 Flawil 1 E-Mail: [email protected] BUCHI reserves the right to make changes to the manual as deemed necessary in the light of experience, especially with respect to structure, illustrations ...

More details
Rotavapor R-100 Operation Manual - Fisher Sci

Rotavapor R-100 Operation Manual - Fisher Sci

Operation Manual Rotavapor R-100 9/60 High internal pressure2.4.2 The evaporation of fluids can produce high pressures inside the flask or the con-denser. If that pressure becomes too great, the glass components could explode. u Make sure that the internal pressure inside the glass components is never greater than atmospheric pressure.

More details
Rotavapor R-100 Operation Manual

Rotavapor R-100 Operation Manual

Operation Manual Rotavapor R-100 9/62 High internal pressure2.4.2 The evaporation of fluids can produce high pressures inside the flask or the con-denser. If that pressure becomes too great, the glass components could explode. u Make sure that the internal pressure inside the glass components is never greater than atmospheric pressure.

More details
How to make your own gin with a Rotavapor

How to make your own gin with a Rotavapor

Rotavapor R-300. The Rotavapor R-300 meets the highest expectations of convenience and versatility in rotary evaporation. Its modular design allows the R-300 to be extended to a fully integrated system where a central interface regulates each component.

More details
Rotavapor - Parts - Evaporation

Rotavapor - Parts - Evaporation

Rotavapor; Rotavapor. View as Grid List. Items 1-9 of 11. Page. You're currently reading page 1; Page 2; Page Next; Show. per page. Sort By. Set Descending Direction. R-300 Support ring, part of a valve unit . $13.00. Add to Cart. Add to Wish List Add to Compare. R-300 Flange screwed connection for glass assembly V/C/A ...

More details
Table of Contents - University of Massachusetts Amherst

Table of Contents - University of Massachusetts Amherst

the Bchi Rotavapor R-220. Always keep these Instructions readily available in the immediate vicinity of the unit so that they make be consulted at any time. Chapter 2 contains important safety rules which must be ob-served to ensure the safe operation of the rotary evaporator. We reserve the right to make technical changes without prior ...

More details
How to get the product (which is a biosurfactant) out of

How to get the product (which is a biosurfactant) out of

The product will then be frozen dried to obtain the powder form. I have read that it has to be dialysed against distilled water, but I am not so sure.

More details
Rotavapor R-300

Rotavapor R-300

The Rotavapor R-300 meets the highest expectations of convenience and versatility in rotary evaporation. Its modular design allows the R-300 to be extended to a fully integrated system where a central interface regulates each component. Evaporating flask size: 50 – 5000 mL. Lift mechanism: Manual or automatic. Temperature range: 20 – 220 C.

More details
20L rotary evaporator manufacturers - TOPTION LAB

20L rotary evaporator manufacturers - TOPTION LAB

TOPTION engineers design most suitable vacuum pump matched with TOPTION brand. rotary evaporator, make your research more accurate and efficient. SHB-III for 0.05L~10L rotary evaporator SHB-B95 for 10L~50L rotary evaporator. 4. Chiller is available for rotary evaporator, so as to meet your special temperature request.

More details
Related Post

Send Message to Us

48-hour idling test machine before leaving the factory. You can take the materials to the factory test machine. We will customize the solution according to your needs.

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.

<script type="text/javascript" src="https://v1.cnzz.com/z_stat.php?id=1281089964&web_id=1281089964"></script>