SOP for Oven of Loss on Drying : Pharmaceutical Guidelines

SOP for Oven of Loss on Drying : Pharmaceutical Guidelines

5.8 Switch off the oven. 5.9 Remove substance place in a desiccator to attain Room Temperature before weighing. 5.10 If drying in the vacuum is required, after step (5.6), connect a vacuum pump to vacuum nozzle allow the desired vacuum to be created, then close the vacuum knob tightly and proceed to step (5.7), maintaining the vacuum ...

More details
Title: Equipment Page 1 of 15 Sections in This Document

Title: Equipment Page 1 of 15 Sections in This Document

6.2. Equipment Qualification A. When new equipment is installed, laboratories may elect to purchase Installation Qualification (IQ) and Operation Qualification (OQ) from the …

More details
Performance Qualification Protocol for Sterilization and Depyrogenating ...

Performance Qualification Protocol for Sterilization and Depyrogenating ...

A deviation indicates variance from the acceptance criteria however, does not necessarily mean that the qualification as unacceptable. During execution of this protocol, if any deviation is noticed, the person executing the protocol initiates a deviation report and provides the detail description of the deviation.

More details
Heating drying ovens for laboratory industry

Heating drying ovens for laboratory industry

Apr 05, 2022 The suitability of the Memmert universal oven UF1060 for use in the cleanroom has been confirmed by the independent Fraunhofer IPA (Institute for Manufacturing Engineering and Automation). It is therefore entitled to bear the certificate Fraunhofer TESTED DEVICE.In order to guarantee the maximum quality assurance, the drying oven was tested in …

More details
QUALIFICATION OF TUNNEL STERILIZING MACHINE

QUALIFICATION OF TUNNEL STERILIZING MACHINE

Aug 28, 2017 Depyrogenation dry heat devices include ovens and tunnel sterilizers. To operate, depyrogenation devices require a series of parameters to be controlled. These parameters include laminar airflow controlled by high-efficiency particulate air (HEPA) filters, with a specification for air velocity and particulates. ... Qualification of established ...

More details
BINDER drying chambers: top-quality laboratory ovens

BINDER drying chambers: top-quality laboratory ovens

BINDER drying chambers are innovative units that combine efficiency and performance with exceptionally high levels of precision and ease of use. The extended temperature range of 5 C to 300 C makes these lab ovens incredibly versatile. Short heat-up times and effective thermal insulation are also part of the long list of features delivered ...

More details
Calibrating Oven Temperature - SciGene

Calibrating Oven Temperature - SciGene

Calibrating Oven Temperature Applicable for Model 400 Hybridization Incubators and Series 700 Microarray Ovens Required part(s): Cat. #1051-52-0— Digital thermometer. Includes cable and NIST certificate. Model 400, 700 and 777 ovens use a …

More details
VALIDATION OF DRY HEAT STERILIZATION METHODS

VALIDATION OF DRY HEAT STERILIZATION METHODS

Dec 28, 2012 As with any sterilization process, the first step in dry-heat sterilizer validation involves qualification of all the equipment and instrumentation used. This step includes examination and documentation of all utilities, ductwork, filters, and control valves or switches for the oven or tunnel unit, and the calibration of the instrumentation ...

More details
Description - Documents for Qualification (IQ/ OQ) LAB

Description - Documents for Qualification (IQ/ OQ) LAB

Documents for Qualification (IQ/ OQ) LAB. Documents for Qualification. Visual, safety, and function test verification that your product complies with the design specifications. The collection of Declaration of Conformity, Declaration of Compliance and the Proprietary Calibration Certificates etc. provide you with all the documents that you need ...

More details
Installation Qualification/Operation Qualification - Labconco

Installation Qualification/Operation Qualification - Labconco

For validation of predetermined FreeZone Freeze Dry Systems and FreeZone Legacy Freeze Dryers specifications. Provides a checklist of installation and operation qualifications to complete when beginning operation on new or used FreeZone Freeze Dry Systems manufactured from 2004 through July 2017 and FreeZone Legacy Freeze Dryers manufactured in August 2017 or …

More details
Performance Qualification Protocol of TUNNEL STERILIZER ...

Performance Qualification Protocol of TUNNEL STERILIZER ...

Jul 18, 2016 Test procedure: Take Dry Ice and check for airflow direction in the zones. Observe the direction of the flow and the same shall be recorded. Acceptance criteria: The stream of air should be unidirectional and non-turbulent up to working zone. Drying zone: airflow towards the vial washing side. Sterilising zone: airflow towards the drying zone.

More details
SOP on Operation Calibration Cleaning and Maintenance of Hot Air Oven ...

SOP on Operation Calibration Cleaning and Maintenance of Hot Air Oven ...

Mar 26, 2016 Switch on the mains of oven. LED lamp for the power indicator will glow. Switch on the fan of the oven. Press and hold the red button given in the temperature control box which will display the pre-set temperature. Set required temperature (250 0C for depyrogenation and 100 0C for drying) using COURSE and FINE temperature adjustment knobs.

More details
Oven Validation Qualification Services Transcat

Oven Validation Qualification Services Transcat

Our technical validation representatives work with you to determine and approve the ideal protocol before on-site work begins. Potential oven validation services include: Endotoxin reduction studies for depyrogenation ovens; 24-hour temperature mapping on laminar flow, convection ovens, and furnaces up to 1,200 degrees Celsius

More details
U.S. Valdiation Services - Depyrogenation Oven

U.S. Valdiation Services - Depyrogenation Oven

Performance Qualification During the PQ of Depyrogenation Oven, each bottle size that will be used during production will be qualified. The study method employed will be that described in Validation of Dry Heat Processes Used For Sterilization and Depyrogenation, Technical Report No. 3, Parenteral Drug Association, 1981.

More details
QUALIFICATION OF AUTOCLAVE

QUALIFICATION OF AUTOCLAVE

Qualification is the integral part of GMP and there is no effective QA program without qualification. Now-a-days it is mandatory to incorporate ... Air leaking into the chamber during the sterilization and drying cycle are not passed through the bacteria retentive filter, and therefore there is a risk of contamination of the load. ...

More details
Sterilization - validation qualification requirements

Sterilization - validation qualification requirements

Sep 19, 2013 6 11 Moist Heat • not suitable for non-aqueous/dry preparations • preferred method of sterilization 12 Dry Heat • Lethality due to oxidative processes • Higher temperatures and longer exposure times required • Typical cycles: – 160C for 120 minutes – 170C for 60 minutes – 180C for 30 minutes – tunnels used for the sterilisation of glass vials may use …

More details
Oven Calibration at Thomas Scientific

Oven Calibration at Thomas Scientific

Standard natural convection constant temperature drying oven with extensive features and simple operation. Digital PID controller, calibration off-set and increased safety+B8:B225 and self diagnostic functions. Operating temp. from ambient +5~300C. Related Products: Oven 300 C. Compare this item.

More details
DG Series Laboratory glassware / instrument drying ovens - Steridium

DG Series Laboratory glassware / instrument drying ovens - Steridium

Steridium engineers have developed the ‘dg-series’ of general drying cabinets and dehydration ovens from the proven laboratory ovens. The unique air-flow system ensures excellent spatial stability throughout the chamber and distributes air evenly over every shelf. The drying cabinets use Steridium's Moisture Extraction system, which ...

More details
Temperature Mapping FDA EU WHO cGMP FLCV

Temperature Mapping FDA EU WHO cGMP FLCV

Temperature mapping is a mandatory requirement whenever regulatory controlled product is being manufactured, and thermal processing or storage is involved (heating or cooling). The individual Operational Qualification (OQ) of the equipment in use, must call for heat distribution; temperature measurement studies of the actual heating or cooling ...

More details
INSTRUCTION MANUAL FOR VACUUM DRYING OVENS

INSTRUCTION MANUAL FOR VACUUM DRYING OVENS

this oven. When connecting the other equipment to the same power supply as this oven, be sure that there is enough power for both units. NOTE: Neither of DP43/63 oven has a plug connected because of the 220V specification. Select a plug suitable to this capacity and connect it. 115V bipolar receptacle Grounding wire

More details